Errata - Corrections to Code Check Books
Code Check Training Centers

Code Check 5th edition, errata to the first printing:

 

Page 5, Table 6, figure reference is to F10, not F30.

Page 5, right column, first subheading under STRUCTURAL SHEATHING/BRACING should read Wall Bracing, not Stud Framing

Page 9, Fig. 14, Basement Window Egress says “3in. min. clearance” and should read “3ft. min. clearance”

Page 9, right column, under INTERIOR WALL COVERS, Greenboard, the “>” symbols should be removed from the 3rd and 4th checkboxes.

Page 10, Fig. 16 - the arrow showing the measurements 36in and 18in should terminate at the glazing edge, not the window frame edge

Page 13, Table 14, note A should read “Based on 1/4in./ft. slope”

Page 13, Table 15, the minimum size for a shower should read [1 1/2in.] 48 {2in.}

Page 13, Table 16, second code reference in the title of the table should be [T2605.1] and in the vertical column, row for plastic, the first number should be [10ft.]

Page 14, under Changes of Direction, a new first line should be added, reading:

Min slope of drains is 1/4in/ft [1/8in/ft for ≥3in pipe]_______________[3005.3]            {708.0}

Page 21, Fig. 50, says "1 sq. in. / 4kBtu each"; should say "1 sq.in. / 2kBtu each"

Page 28, Top left, major heading APPLIANCES should read CABLE SYSTEMS

Page 28, Top right, major heading APPLIANCES, should read RACEWAYS

Page 28, Top right, first subheading General Rules for NM, UF, SE &  AC, should read General

Page 29, Left column, third subheading Lighting outlets, fourth bullet point, should read "Indoors 7 1/2 ft..." not "Indoors 72ft..."

 